NHB-110 premium features and benefits
2" venting up to 65';
3” up to 150’ (including schedule 40 PVC).
The condensing technology of the dual stainless steel heat exchangers saves energy, reduces greenhouse gasses.
The sophisticated gas flow control system provides a high turndown ratio which reduces energy waste and excessive boiler cycling.
The sophisticated gas flow control system provides a high turndown ratio which reduces energy waste and excessive boiler cycling.
NHB integrated control provides industry-leading options and features including adjustable heat capacity, temp boost for outdoor reset control, adjustable anti-cycle timer and freeze protection.
1/2" gas pipe capability up to 24' (subject to local codes). Cuts installation time, no need to install new gas lines for retrofit applications.
NHB-110 QuickFacts
17.0" W x 24.0" H x 13.0" D (43.2cm W x 61.0cm H x 33.0cm D)
Product approvals
- CSA
- Yes
- SCAQMD 1146.2(NOx, <20ppm)
- Yes
- ASME Certified
- Yes "H" Stamp
- AHRI Number
- 7501497
- Energy star certified
- Yes
Space Heating Ratings
- AFUE, %
- 95.0
- Heating Capacity
- 102,000 BTU/h (29.9 kWh)
Model | NHB-110 |
---|---|
Range | 10,000 - 110,000 BTU/h (2.93 - 32.23 kWh) |
TDR | 11:1 |
Navien Condensing Boiler Space Heating Ratings | ||
---|---|---|
Model1 | NHB-110 | |
Heating Input | Min | 10,000 BTU/h (2.9 kWh) |
Max | 110,000 BTU/h (32.2 kWh) | |
Heating Capacity2 | 102,000 BTU/h (29.9 kWh) | |
Net AHRI Rating, Water3 | 89,000 BTU/h (26.1 kWh) | |
AFUE2, % | 95.0 |
1 Ratings are the same for Natural Gas models converted to Propane use.
2 Based on U.S. Department of Energy (DOE) test procedures.
3 The NET AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15. Consult Navien before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.
Item | NHB-110 | |
---|---|---|
Dimensions | 17.0" W x 24.0" H x 13.0" D (43.2cm W x 61.0cm H x 33.0cm D) | |
Boiler weight | 80 lbs (36.3 kg) | |
Installation location | Indoor wall-hung | |
Venting type | Forced draft direct vent | |
Ignition | Electronic ignition | |
Natural gas supply pressure (from source) | 3.5 " WC to 10.5 " WC (0.87 kPa to 2.61 kPa) | |
Propane gas supply pressure (from source) | 8 " WC to 13 " WC (1.99 kPa to 3.23 kPa) | |
Natural gas manifold pressure | -0.1 " WC (-0.025 kPa) | |
Propage gas manifold pressure | -0.09 " WC (-0.022 kPa) | |
Connection sizes | Gas inlet | 3/4" NPT (hembra) |
Power supply | Main supply | 120V AC, 60Hz |
Maximum power consumption | Less than 10A | |
Materials | Casing | Cold rolled carbon steel |
Heat exchangers | Primary and secondary heat exchangers: stainless steel | |
Venting | Exhaust | 2" or 3" PVC, CPVC, approved polypropylene (see installation manual for more details) 2" or 3" special gas vent type BH (Class III, A/B/C) |
Intake | 2" or 3" PVC, CPVC, polypropylene 2" or 3" special gas vent type BH (Class III, A/B/C) | |
Vent clearances | 0" to combustibles | |
Safety Devices | Flame rod, APS, gas valve operation detector, ignition operation detector, water temperature high limit switch, exhaust temperature high limit sensor |
Navien reserves the right to change specifications at any time without prior notice.